Izvestiya of Saratov University.

Chemistry. Biology. Ecology

ISSN 1816-9775 (Print)
ISSN 2541-8971 (Online)


Full text:
(downloads: 84)
Language: 
Russian
Heading: 
Article type: 
Article

Electroanalytical Properties of Non-modified and Polyaniline Modified Solid Contact Cefazolin Selective Sensors

Autors: 
Kulapina Elena Grigorievna, Saratov State University
Kulapina Olga Ivanovna, Saratov State Medical University
Dubasova Anastasia Е., Saratov State University
Abstract: 

Cefazolin is a cephalosporin antibiotic of the third generation. It is widely used in medical practice for the therapy of various infectious-somatic pathologies. The work was aimed at the creation of solid-contact potentiometric cefazolin-selective sensors. For the first time, polyaniline was used to stabilize the potentials of solid-contact sensors. As the membranes active components, the compound of tetradecylammonium (TDA) with the silver (I) – cefazolin complex were applied. Research tasks: determination of optimal membrane compositions of unmodified and polyaniline modified sensors, choice of conditions deposition of a modifier to the surface of membranes.A comparative evaluation of the electroanalytical and transport properties of membranes of unmodified and polyaniline modified cefazolin-selective sensors has been carried out. For modified sensors, the angular coefficients of the electrode functions were found to correspond to theoretical values. The decrease of the response time, the membrane resistance, and the error of antibiotic determination has been established. The possibility of the new modified sensors application for the determination of cefazolin in aqueous media has been shown; the relative error varies within the ranged from 2–4%.

Reference: 

1. Кулапина Е. Г., Чернова Р. К., Кулапин А. И. Потенциометрические сенсоры для определения синтетических поверхностно-активных веществ. Саратов : Науч. кн., 2008. 179 с.

2. Bobacka J., Lindfors T., McCarrick M., Ivaska A., Levenstam A. Single-piece all-solid-stateion-selective electrode // Anal. Chem. 1995. Vol. 67, № 20. P. 3819–3824.

3. Bobacka J., McCarrick M., Ivaska A., Levenstam A., Ivaska A. All-solid-state poly(vinilcloride) membrane ion-selective electrode with poly(3-octylthiophene) solid internal contact // Analyst. 1994. Vol. 119. P. 1985–1991.

4. Cadogan A., Gao Z., Levenstam A., Ivaska A. All-solidstate sodium-selective electrode based on a calixareneionophore in a poly (vinyl chloride) membrane with a polypyrrole solid contact // Anal. Chem. 1992. Vol. 64, № 21. Р. 2496–2501.

5. Маркузина Н. Н., Дмитриева И. В. Применение электронопроводящего полимера полианилина для стабилизации потенциала твердоконтактных электродов // Изв. СПбГЭТУ «ЛЭТИ». 2009. № 9. С. 69–74.

6. Кузнецова М. В., Рясенский С. С., Горелов И. П. Твердотельные ионоселективные электроды для определения димедрола // Хим.-фарм. журн. 2003. Т. 37, № 11. С. 34–36.

7. Картамышев С. В., Кузнецова М. В., Рясенский С. С., Горелов И. П. Твердотельные ионоселективные элек- троды обратимые к анаприлину // Хим.-фарм. журн. 2005. Т. 39, № 1. С. 42–44.

8. Картамышев С. В., Кузнецова М. В., Рясенский С. С., Горелов И. П. Папаверин-селективные электроды с ионо-электронным трансдьюсером на основе электро- проводного полимера поли(?-нафтиламина) // Хим.- фарм. журн. 2005. Т. 39, № 2. С. 42–44.

9. Кулапина О. И., Кулапина Е. Г. Антибактериальная терапия. Современные методы определения анти- биотиков в биологических и лекарственных средах. Саратов : Сарат. источник, 2015. 91 с.

10. Белюстин А. А. Потенциометрия : физико-химические основы и применения. СПб. : Лань, 2015. С. 155–157.